A miniature capacitive probe array for transient high voltage capillary discharges
Abstract
The design and construction of a millimeter size noninvasive capacitive probe array to investigate ionization growth phenomena in pulsed capillary discharges are presented. The probes estimated to be characterized by a time response better than 0.5 ns, with very good electric noise rejection. The probes have identified a fast ionization wave in the prebreakdown phase of a hollow cathode initiated fast pulsed capillary discharge. © 2001 American Institute of Physics.
Más información
| Título según WOS: | A miniature capacitive probe array for transient high voltage capillary discharges | 
| Título según SCOPUS: | A miniature capacitive probe array for transient high voltage capillary discharges | 
| Título de la Revista: | REVIEW OF SCIENTIFIC INSTRUMENTS | 
| Volumen: | 72 | 
| Número: | 4 | 
| Editorial: | AMER INST PHYSICS | 
| Fecha de publicación: | 2001 | 
| Página de inicio: | 2186 | 
| Página final: | 2190 | 
| Idioma: | English | 
| URL: | http://scitation.aip.org/content/aip/journal/rsi/72/4/10.1063/1.1359191 | 
| DOI: | 10.1063/1.1359191 | 
| Notas: | ISI, SCOPUS | 