Determination of antimony in soils and vegetables by hydride generation atomic fluorescence spectrometry and electrothermal atomic absorption spectrometry. Optimization and comparison of both analytical techniques

De Gregori, I; Pinochet, H.; Fuentes E.; Potin-Gautier, M

Abstract

Two sensitive analytical atomic spectrometry methods, electrothermal atomic absorption spectrometry (ET-AAS) and hydride generation coupled to atomic fluorescence spectroscopy (HG-AFS), were optimized for determining total antimony in soils and plant (alfalfa) matrices. The dry soils were digested with HNO3-HCl-HF mixture, while, for the freeze dry alfalfa samples, HNO3-H2SO4-H2O2 or HNO3-H2O2 mixtures were used. The microwave oven digestion procedures chosen allowed the total dissolution of the matrices. The experimental parameters of both spectrometric techniques were optimized using standard solutions of Sb(III) and/or Sb(V), and digested solutions of soil and alfalfa samples. Since in the antimony determination by HG-AFS the kinetic of the hydride generation is dependent on the antimony oxidation state, a chemical reduction of Sb(V) to Sb(III) was carried out prior to the stibine generation. For this purpose, KI and L-cysteine were used as reducing agents, assaying different experimental conditions. The reduction of Sb(V) in plant solutions by a KI-ascorbic acid mixture can be performed at room temperature, while the Sb(V) reduction from soils solutions was quantitative when the procedure was accomplished in a microwave oven or at 90°C in a water bath. For antimony determination by HG-AFS, the simple calibration mode was used, because this technique is less sensitive to interferences. For antimony determination by ET-AAS the use of a chemical modifier is unavoidable. Similar amounts of nickel or palladium were effective in stabilizing the antimony species present in soils and plant solutions; however, the best analytical signals were obtained using mixtures of this metals with NH4H2PO4 and citric acid. Due to the matrix interference for determining antimony by ET-AAS, the standard additions method was used. The accuracy of the proposed methods were assessed by analyzing two certified reference soils (CRM) from NIST, San Joaquin soil (SRM 2709) and Montana soil (SRM 2710) and a reference vegetal material, Virginia tobacco leaves (CTA-VTL-2).

Más información

Título según WOS: Determination of antimony in soils and vegetables by hydride generation atomic fluorescence spectrometry and electrothermal atomic absorption spectrometry. Optimization and comparison of both analytical techniques
Título según SCOPUS: Determination of antimony in soils and vegetables by hydride generation atomic fluorescence spectrometry and electrothermal atomic absorption spectrometry. Optimization and comparison of both analytical techniques
Título de la Revista: JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Volumen: 16
Número: 2
Editorial: ROYAL SOC CHEMISTRY
Fecha de publicación: 2001
Página de inicio: 172
Página final: 178
Idioma: English
URL: http://xlink.rsc.org/?DOI=b008568p
DOI:

10.1039/b008568p

Notas: ISI, SCOPUS