Water-fat Dixon cardiac magnetic resonance fingerprinting
Abstract
Purpose: Cardiac magnetic resonance fingerprinting (cMRF) has been recently introduced to simultaneously provide T1, T2, and M0 maps. Here, we develop a 3-point Dixon-cMRF approach to enable simultaneous water specific T1, T2, and M0 mapping of the heart and fat fraction (FF) estimation in a single breath-hold scan. Methods: Dixon-cMRF is achieved by combining cMRF with several innovations that were previously introduced for other applications, including a 3-echo GRE acquisition with golden angle radial readout and a high-dimensional low-rank tensor constrained reconstruction to recover the highly undersampled time series images for each echo. Waterâfat separation of the Dixon-cMRF time series is performed to allow for water- and fat-specific T1, T2, and M0 estimation, whereas FF estimation is extracted from the M0 maps. Dixon-cMRF was evaluated in a standardized T1âT2 phantom, in a waterâfat phantom, and in healthy subjects in comparison to current clinical standards: MOLLI, SASHA, T2-GRASE, and 6-point Dixon proton density FF (PDFF) mapping. Results: Dixon-cMRF water T1 and T2 maps showed good agreement with reference T1 and T2 mapping techniques (R2 > 0.99 and maximum normalized RMSE ~5%) in a standardized phantom. Good agreement was also observed between Dixon-cMRF FF and reference PDFF (R2 > 0.99) and between Dixon-cMRF water T1 and T2 and water selective T1 and T2 maps (R2 > 0.99) in a waterâfat phantom. In vivo Dixon-cMRF water T1 values were in good agreement with MOLLI and water T2 values were slightly underestimated when compared to T2-GRASE. Average myocardium septal T1 values were 1129 ± 38 ms, 1026 ± 28 ms, and 1045 ± 32 ms for SASHA, MOLLI, and the proposed water Dixon-cMRF. Average T2 values were 51.7 ± 2.2 ms and 42.8 ± 2.6 ms for T2-GRASE and water Dixon-cMRF, respectively. Dixon-cMRF FF maps showed good agreement with in vivo PDFF measurements (R2 > 0.98) and average FF in the septum was measured at 1.3%. Conclusion: The proposed Dixon-cMRF allows to simultaneously quantify myocardial water T1, water T2, and FF in a single breath-hold scan, enabling multi-parametric T1, T2, and fat characterization. Moreover, reduced T1 and T2 quantification bias caused by waterâfat partial volume was demonstrated in phantom experiments.
Más información
| Título según WOS: | Water-fat Dixon cardiac magnetic resonance fingerprinting |
| Título según SCOPUS: | Waterâfat Dixon cardiac magnetic resonance fingerprinting |
| Título de la Revista: | Magnetic Resonance in Medicine |
| Volumen: | 83 |
| Número: | 6 |
| Editorial: | John Wiley and Sons Inc. |
| Fecha de publicación: | 2020 |
| Página de inicio: | 2107 |
| Página final: | 2123 |
| Idioma: | English |
| DOI: |
10.1002/mrm.28070 |
| Notas: | ISI, SCOPUS |