Effect of maturity on soot volume fraction measurements using the AC-LII technique in a laminar coflow ethylene diffusion flame

Fuentes, Andres

Abstract

The auto-compensating laser-induced incandescence (AC-LII) technique has been frequently used to measure soot volume fraction (fv) in flames. AC-LII relies on an assumption about the spectral variation of soot absorption function E(m,?) at the two detection wavelengths for soot temperature determination. It has been a common practice to assume a constant E(m,?) based on the believe that LII measures mature soot only. Since soot maturity in flames is a continuous phenomenon from young to mature, it is unclear how soot maturity affects the AC-LII measured fv. In this study, a correction to the AC-LII measured fv with the conventional hypothesis of mature soot is proposed based on the soot maturity coefficient ? and absorption function E(m,?) in a laminar coflow ethylene diffusion flame. The application of this correction is first demonstrated for synthetic time-resolved LII signals based on the spatial distribution of soot properties in the ethylene diffusion flame predicted by the CoFlame code. A significant decrease of the simulated incandescence signals SLII and soot temperature Teff is observed when the maturity coefficient is increased from 0 for fully mature soot to 1.2 for highly immature soot. Then the proposed correction is applied to AC-LII measured fv in the same flame with the help of spatial distributions of ? and ratio of spectrally-resolved E(m,?) by multiwavelength line-of-sight attenuation and emission (MW-LOSA/EMI) measurements. The uncorrected AC-LII measured fv is in general significantly lower than that measured by MW-LOSA/EMI, which inherently considers soot maturity. The corrected AC-LII fv results are in good agreement, within the experimental error, with those measured by MW-LOSA/EMI. Therefore, the proposed methodology can quantify the effect of soot maturity on AC-LII measured fv and largely eliminate the difference in the measurements of fv by AC-LII and MW-LOSA/EMI. © 2022 The Combustion Institute

Más información

Título según WOS: Effect of maturity on soot volume fraction measurements using the AC-LII technique in a laminar coflow ethylene diffusion flame
Título según SCOPUS: Effect of maturity on soot volume fraction measurements using the AC-LII technique in a laminar coflow ethylene diffusion flame
Título de la Revista: Proceedings of the Combustion Institute
Volumen: 39
Número: 1
Editorial: Elsevier Ltd.
Fecha de publicación: 2023
Página de inicio: 1505
Página final: 1514
Idioma: English
DOI:

10.1016/j.proci.2022.10.013

Notas: ISI, SCOPUS