Análisis de aceite en motores de combustión interna estacionarios de planta de generación de energía eléctrica
Keywords: SACODE, análisis de aceite, condición del aceite
Abstract
In the present work, an integrated quality analysis process of the lubricating oil used in stationary diesel engines of electric power plants is implemented. This process includes a continuous monitoring of relevant variables through the well-known methodology SACODE with the following modifications: changes in variable limits and evaluation of kinematic viscosity and TBN by using Fuzzy logic. The method of analysis was automated by the implementation of the software SOFTLUB on the MATLAB platform. The uses of SOFTLUB allowed graphing historical results of oil quality parameters, calculating and updating its limits, quality assessment and also predicting future behavior of oil viscosity and TBN, in order to support maintenance decision making in power plants
Más información
Título de la Revista: | REVISTA TECNICA DE LA FACULTAD DE INGENIERIA UNIVERSIDAD DEL ZULIA |
Volumen: | 37 |
Número: | 3 |
Editorial: | Universidad del Zulia |
Fecha de publicación: | 2014 |
Página de inicio: | 206 |
Página final: | 212 |
Idioma: | Español |
URL: | http://ve.scielo.org/scielo.php?script=sci_arttext&pid=S0254-07702014000300003&lng=es&tlng=es. |