Double-layered Water Cherenkov Detector for SWGO

Kunwar S.; Abreu P.; Albert A.; Angüner E.O.; Arcaro C.; Arnaldi L.H.; Arteaga-Velázquez J.C.; Assis P.; Bakalová A.; de Almeida U.B.; Batković I.; Bellido J.; Belmont-Moreno E.; Bisconti F.; Blanco A.; et. al.

Abstract

The Southern Wide-field Gamma-ray Observatory (SWGO) will use the well-established and cost-effective technique of detecting Cherenkov light produced in water-filled detection units for TeV gamma-ray astronomy. Leveraging detector material reflectivity together with an optimised aspect ratio is an option to improve the performance of an array of such detector units. The double-layered Water Cherenkov Detector units comprise chambers with single photosensors in each. A reflective upper compartment enhances sensitivity to impinging secondary particles. A shallow lower compartment enables muon tagging and consequently improves the gamma hadron separation power of the observatory. Here we present detailed studies on the double-layered unit design.

Más información

Título según SCOPUS: Double-layered Water Cherenkov Detector for SWGO
Título de la Revista: Proceedings of Science
Volumen: 395
Editorial: Sissa Medialab Srl
Fecha de publicación: 2022
Idioma: English
Notas: SCOPUS