Electrodialytic separation of Cu(II) and As(V) in acidic electrolytes Separación electrodialítica de Cu(II) y As(V) en electrolitos ácidos
Keywords: copper, temperature, electrolytes, speciation, density, transport, separation, arsenic, acidic, phase, ph, electrodialysis, effects, room, current, compounds, Rate
Abstract
The separation of copper and arsenic from acidic electrolytes by electrodialysis was investigated at room temperature. The effect of current density and pH was studied in a batch cell during 3 hours. The kinetic parameters showed that Cu(II) transport rate was 0.75 mol/m 2/h and the As(V) transport rate was 0.002 mol/m 2/h. An efficient separation between Cu(II) and As(V) was achieved; generating a concentrated solution of copper with no arsenic, which was obtained independently of the electrolyte acidity and current density used. The effect of the arsenic speciation with pH is discussed as well.
Más información
Título de la Revista: | REVISTA DE METALURGIA |
Volumen: | 43 |
Número: | 1 |
Editorial: | CENIM |
Fecha de publicación: | 2007 |
Página de inicio: | 5 |
Página final: | 10 |
URL: | http://www.scopus.com/inward/record.url?eid=2-s2.0-33847718278&partnerID=q2rCbXpz |