Operation of regenerative cascade multicell converter under fault condition
Keywords: modulation, degree, fault, location, faults, power, drives, converters, operation, output, pwm, dc, theorem, operations, powers, tolerant, generators, electronics, loads, rectifiers, codes, ranges, width, pulse, internal, presentations, of, conditions, normal, Electric, High, Critical, proving, technical, Turn, voltages, (symbols), multicell, freedoms, Phase-shift, offs
Abstract
Reliability and fault tolerant operation are key aspects in high power drives, specially when these drives are used to operate critical loads, as downhill conveyors. This paper presents a solution for the operation under internal fault of high power regenerative Cascade Multicell Converter, which allows to operate temporally in normal conditions or to turn off the equipment in a controlled way. Previous works have shown that it is possible to reduce the effects on the load due to internal faults by modifying the phase-shift between the output voltages. The proposed method uses the additional degree of freedom given by the controlled dc-link voltage of the PWM rectifiers, to increase the operation range, even reaching non-fault operation. ©2008 IEEE.
Más información
Título de la Revista: | 2008 IEEE 11TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS |
Editorial: | IEEE |
Fecha de publicación: | 2008 |
Página de inicio: | 48 |
Página final: | 53 |
URL: | http://www.scopus.com/inward/record.url?eid=2-s2.0-56649113133&partnerID=q2rCbXpz |