Improved Active Power Filter Performance for Renewable Power Generation Systems

Acuna P.; Morán L; Rivera M.; Dixon J.; Rodriguez J.

Abstract

An active power filter implemented with a four-leg voltage-source inverter using a predictive control scheme is presented. The use of a four-leg voltage-source inverter allows the compensation of current harmonic components, as well as unbalanced current generated by single-phase nonlinear loads. A detailed yet simple mathematical model of the active power filter, including the effect of the equivalent power system impedance, is derived and used to design the predictive control algorithm. The compensation performance of the proposed active power filter and the associated control scheme under steady state and transient operating conditions is demonstrated through simulations and experimental results.

Más información

Título según WOS: Improved Active Power Filter Performance for Renewable Power Generation Systems
Título de la Revista: IEEE TRANSACTIONS ON POWER ELECTRONICS
Volumen: 29
Número: 2
Editorial: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Fecha de publicación: 2014
Página de inicio: 687
Página final: 694
Idioma: English
URL: http://ieeexplore.ieee.org/lpdocs/epic03/wrapper.htm?arnumber=6497639
DOI:

10.1109/TPEL.2013.2257854

Notas: ISI