Detection of Intracoronary Thrombus by Magnetic Resonance Imaging in Patients With Acute Myocardial Infarction

Jansen, C. H. P.; Perera, D.; Makowski M.R.; Wiethoff, A. J.; Phinikaridou A.; Razavi, R. M.; Marber, M. S.; Greil G.F.; Nagel E.; Maintz, D.; Redwood, S.; Botnar R.M.

Abstract

Background-Persistent intracoronary thrombus after plaque rupture is associated with an increased risk of subsequent myocardial infarction and mortality. Coronary thrombus is usually visualized invasively by x-ray coronary angiography. Non-contrast-enhanced T1-weighted magnetic resonance (MR) imaging has been useful for direct imaging of carotid thrombus and intraplaque hemorrhage by taking advantage of the short T1 of methemoglobin present in acute thrombus and intraplaque hemorrhage. The aim of this study was to investigate the use of non-contrast-enhanced MR for direct thrombus imaging (MRDTI) in patients with acute myocardial infarction. Methods and Results-Eighteen patients (14 men; age, 61 +/- 9 years) underwent MRDTI within 24 to 72 hours of presenting with an acute coronary syndrome before invasive x-ray coronary angiography; MRDTI was performed with a T1-weighted, 3-dimensional, inversion-recovery black-blood gradient-echo sequence without contrast administration. Ten patients were found to have intracoronary thrombus on x-ray coronary angiography (left anterior descending, 4; left circumflex, 2; right coronary artery, 4; and right coronary artery-posterior descending artery, 1), and 8 had no visible thrombus. We found that MRDTI correctly identified thrombus in 9 of 10 patients (sensitivity, 91%; posterior descending artery thrombus not detected) and correctly classified the control group in 7 of 8 patients without thrombus formation (specificity, 88%). The contrast-to-noise ratio was significantly greater in coronary segments containing thrombus (n = 10) compared with those without visible thrombus (n = 131; mean contrast-to-noise ratio, 15.9 versus 2.6; P < 0.001). Conclusion-Use of MRDTI allows selective visualization of coronary thrombus in a patient population with a high probability of intracoronary thrombosis. (Circulation. 2011; 124: 416-424.)

Más información

Título según WOS: Detection of Intracoronary Thrombus by Magnetic Resonance Imaging in Patients With Acute Myocardial Infarction
Título de la Revista: CIRCULATION
Volumen: 124
Número: 4
Editorial: LIPPINCOTT WILLIAMS & WILKINS
Fecha de publicación: 2011
Página de inicio: 416
Página final: 424
Idioma: English
URL: http://circ.ahajournals.org/cgi/doi/10.1161/CIRCULATIONAHA.110.965442
DOI:

10.1161/CIRCULATIONAHA.110.965442

Notas: ISI