Fast image reconstruction in fluoresence optical tomography using data compression

Rudge,Timothy J.; Soloviev, Vadim Y.; Arridge, Simon R.

Abstract

We present a method for fast reconstruction in flourescence optical tomography with very large data sets. In recent reports, CCD cameras at multiple positions have been used to collect optical measurements, producing more than 107 data samples. This makes storage of the full system Jacobian infeasible, and so data are usually subsampled. The method reported here allows use of the full data set, via image compression methods, and explicit construction of the (small) Jacobian, meaning optimal inversion methods can be applied, and thus leading to very fast reconstruction. (C) 2010 Optical Society of America

Más información

Título según WOS: Fast image reconstruction in fluoresence optical tomography using data compression
Título de la Revista: OPTICS LETTERS
Volumen: 35
Número: 5
Editorial: OPTICAL SOC AMER
Fecha de publicación: 2010
Página de inicio: 763
Página final: 765
DOI:

10.1364/OL.35.000763

Notas: ISI