Preparation and application of nanocomposite based on imprinted poly (methacrylic acid)-PAN/MWCNT as a new electrochemical selective sensing platform of Pb2+ in water samples

Teixeira Tarley, Cesar Ricardo; Basaglia, Andreia Montani; Segatelli, Mariana Gava; Prete, Maiyara Carolyne; Cajamarca Suquila, Fabio Antonio; Goncalves de Oliveira, Leandro Luan

Abstract

This paper describes the development of an electrochemical sensor highly selective to Pb2+ ions based on drop coated glassy carbon electrode (GCE) with a suspension of ion imprinted polymer (IIP) loaded with 1-(2-pyridylazo)-2-naphthol (PAN) (IIP-PAN) and multi -walled carbon nanotubes (MWCNT). The polymer has been characterized by SEM and TGA. The electrochemical method is based on open -circuit preconcentration of Pb2 + onto modified electrode in 0.05 mol L-1 Tris-HC1 buffer solution at pH 6.0 during 20 min. The reduction of Pb2+ was than performed on closed circuit at - 1.2 V during 60 s in a 0.05 mol L-1 HCl solution, followed by subsequent differential pulse anodic stripping voltammetric determination in the range from - 0.8 to - 0.3 V. Electrode modified provided a better analytical response than those modified with its respective non imprinted polymer (NIP), IIP without PAN and MWCNT alone, which clearly demonstrates the synergic effect of recognition sites of IIP-PAN and MWCNT. Competitive adsorption studies for the binary Pb2+/Cu2+, Pb2 +/C2+, pb(2+)/Ni2+, pb(2+)/Ni2+ pb(2+)/Zn2+ mixtures revealed the respective relative selective coefficients (k(r)) 301, 13.3, 9.5, 63.0 and 133.3, thus indicating that HP -PAN is much more selective than NIP. Presence of potential interfering metal ions was also studied and the proposed electrode proved to be very tolerable. Limits of detection (LOD) and quantification (LOQ) were found to be 0.16 rho g L-1 and 0.50 mu g L-1, respectively. The inter day method precision was found to be 1.72 and 1.86% (relative standard deviation) and the infra-day precision was found to be 1.68 and 2.53% for 5.0 and 10.0 mu g L-1 of Pb2 +, respectively. The developed sensor was effectively applied to water samples and synthetic urine with satisfactory recovery values from 95 to 103%. The accuracy of method was checked by analysis of standard reference material 1643e Trace Elements in Water NIST.

Más información

Título según WOS: ID WOS:000411847500017 Not found in local WOS DB
Título de la Revista: JOURNAL OF ELECTROANALYTICAL CHEMISTRY
Volumen: 801
Editorial: Elsevier
Fecha de publicación: 2017
Página de inicio: 114
Página final: 121
DOI:

10.1016/j.jelechem.2017.07.033

Notas: ISI