Influence of different plasticizers on the response of chemical sensors based on polymeric membranes for nitrate ion determination

Perez, MD; Marin, LP; Quintana, JC; Yazdani-Pedram, M

Abstract

Seven types of ion-selective chemical sensors based on poly(vinyl chloride) (PVC) as polymeric membrane, for determination of nitrate ion, have been prepared by using 3-nitro-o-xylene (NOX), tributylphosphate (TBP), bis-(2-ethylhexyl) sebacate (DOS), o-nitrophenyloctyl ether (o-NPOE), tris-2-ethylhexylphosphate (TEHP), dioctylphthalate (DOP) and dibutylphthalate (DBP) as plasticizers and tetradecil ammonium nitrate (TDAN) as ionophore. The response of each electrode was determined in relation to the lipophilicity of the plasticizer used, its rate of exudation to the aqueous phase, polarity, viscosity and its dielectric constant (?r). The experimental data was validated by calibrating the constructed electrodes against a reference Ag/AgCl electrode. The selectivity coefficient (KABPot) of the electrodes was determined by applying the standard mixed solutions method. No correlation between KABPot and ?r of the plasticizer was found. ATR-FT-IR technique was used in order to evaluate the life-time of the polymeric membranes ion-selective electrodes (ISEs). The life-time of the electrodes was found to be limited fundamentally by the loss of the sensor and not due to the loss of the plasticizer. All the constructed ISEs showed Nernstian slopes with values of the practical detection limit (PDL) and lower limit of linear response (LLLR) in the range 10-6 to 10-5mol/dm3. The electrodes constructed by using o-NPOE and/or DBP showed the longest life-time, this being longer than 6 months. The principal interfering anions were found to be ClO3-, BrO3-, Br-, Cl- and Bz- (benzoate). The selectivity loss of the sensors was found to be due to the loss of the ionophore by exudation. No correlation between the calculated values for KABPot of the electrodes and the dielectric constants of the plasticizers was observed. © 2003 Elsevier Science B.V. All rights reserved.

Más información

Título según WOS: Influence of different plasticizers on the response of chemical sensors based on polymeric membranes for nitrate ion determination
Título según SCOPUS: Influence of different plasticizers on the response of chemical sensors based on polymeric membranes for nitrate ion determination
Título de la Revista: SENSORS AND ACTUATORS B-CHEMICAL
Volumen: 89
Número: 3
Editorial: ELSEVIER SCIENCE SA
Fecha de publicación: 2003
Página de inicio: 262
Página final: 268
Idioma: English
URL: http://linkinghub.elsevier.com/retrieve/pii/S0925400502004756
DOI:

10.1016/S0925-4005(02)00475-6

Notas: ISI, SCOPUS