Assessment of parameters governing the steel fiber alignment in fresh cement-based composites
Abstract
The main aim of this paper is to measure the induced torque needed to rotate a steel fiber, hence an experimental and parametrical analysis of factors governing steel fiber alignment in cement pastes and mortar, rotating from static position and rotating in a dynamic fluid is here presented. To aim this objective, a set of rheological tests has been conducted to assess the torque necessary to rotate steel fibers immersed into different fresh cement paste and mortar mixes with Bingham fluid behaviour. Fibers of different aspect ratios (length/width) and different geometry, straight and hooked-end, have been evaluated as they are the more commonly used. On the other hand, different parameters (type of mixture, size of aggregates, volume fraction of aggregates) affecting cement mixtures are also analysed and their influence in fiber orientation discussed. Fiber alignment depends on external torques applied to fibers, immersed into a cement-water aggregate viscous system, that can be produced during or after casting. The flowability of the fresh suspension with fibers produces a load/pressure that generates a torque that can align them. Fiber alignment is a main goal to pump the fresh material. Hence, the factors that govern fiber alignment are studied which increase the post-cracking strength of cement-based composites under load along its life service due to casting or pumping. To that end, a set of tests has been conducted to assess the torque necessary to rotate steel fibers immersed into different fresh cement paste and mortar mixes with Bingham fluid behaviour. Fibers of different aspect ratios(length/width) and different geometry (straight and hooked-end) have been evaluated. On the other hand, different parameters (type of mixture, size of aggregates, volume fraction of aggregates) affecting cement mixtures are also analysed and their influence on fiber orientation is discussed. The values obtained here are between 1 and 14 N . mm of dynamic yield torque and 0.1 and 0.5 N . mm min for viscoplastic torque per fiber, depending on fiber geometry, are helpful to improve the fiber alignment in cement-based composites reinforced with fibers through a design and production based on these parameters. (C) 2019 Published by Elsevier Ltd.
Más información
| Título según WOS: | ID WOS:000468253600049 Not found in local WOS DB |
| Título de la Revista: | Construction and Building Materials |
| Volumen: | 207 |
| Editorial: | Elsevier Ltd. |
| Fecha de publicación: | 2019 |
| Página de inicio: | 548 |
| Página final: | 562 |
| DOI: |
10.1016/j.conbuildmat.2019.02.036 |
| Notas: | ISI |