Operation of high-power cycloconverter-fed gearless drives under abnormal conditions

Pontt, JO; Rodriguez, JP; Rebolledo, JC; Tischler, K; Becker, N

Abstract

This paper presents the behavior of large power mills (more than 10 MW each) that are fed by cycloconverters. Special attention is dedicated to the protection philosophy to avoid operational interruptions that can produce huge production losses and equipment damage. Several failure possibilities are considered: control failure, complete power outage, if a thyristor fails and cannot block reverse voltage, etc. Simulation studies and field measurements show that large currents and torque can occur under certain circumstances and that motor foundations must be able to support them. As a general conclusion, it can be said that proper protective design effectively avoids equipment damage. © 2007 IEEE.

Más información

Título según WOS: Operation of high-power cycloconverter-fed gearless drives under abnormal conditions
Título según SCOPUS: Operation of high-power cycloconverter-fed gearless drives under abnormal conditions
Título de la Revista: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
Volumen: 43
Número: 3
Editorial: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Fecha de publicación: 2007
Página de inicio: 814
Página final: 820
Idioma: English
URL: http://ieeexplore.ieee.org/lpdocs/epic03/wrapper.htm?arnumber=4215019
DOI:

10.1109/TIA.2007.895807

Notas: ISI, SCOPUS