Evaluation of the operating performance of conventional versus flocculator secondary clarifiers at the Kuwahee Wastewater Treatment Plant, Knoxville, Tennessee
Abstract
The difference in performance of three differently designed circular secondary clarifiers in the same wastewater treatment plant was analyzed in this paper. Data obtained using flocculated suspended solids and disperse suspended solids tests were analyzed using statistical tools. The conventional clarifier showed more variability in the average effluent suspended solids concentration when compared with the flocculator-clarifiers. Furthermore, a difference in performance among the two different flocculator-clarifiers was found.
Más información
Título según WOS: | Evaluation of the operating performance of conventional versus flocculator secondary clarifiers at the Kuwahee Wastewater Treatment Plant, Knoxville, Tennessee |
Título según SCOPUS: | Evaluation of the operating performance of conventional versus flocculator secondary clarifiers at the Kuwahee wastewater treatment plant, Knoxville, Tennessee |
Título de la Revista: | WATER ENVIRONMENT RESEARCH |
Volumen: | 79 |
Número: | 5 |
Editorial: | Wiley |
Fecha de publicación: | 2007 |
Página de inicio: | 547 |
Página final: | 553 |
Idioma: | English |
URL: | http://openurl.ingenta.com/content/xref?genre=article&issn=1061-4303&volume=79&issue=5&spage=547 |
DOI: |
10.2175/106143006X123166 |
Notas: | ISI, SCOPUS |