Performance of the cerebral state index during increasing levels of propofol anesthesia: A comparison with the bispectral index
Abstract
BACKGROUND: The cerebral state monitor is a new device to measure depth of anesthesia. In this study we compared the cerebral state monitor with the bispectral index (BIS) monitor during propofol anesthesia. METHODS: Fifteen healthy patients received a continuous infusion of propofol (300 mL/h). The cerebral state index (CSI) and the BIS values were recorded until burst suppression ratio ≥60%. Baseline variability, prediction probability, and agreement analysis between indices were evaluated. Clinical markers of loss of consciousness were also assessed. RESULTS: Mean awake BIS and CSI values were 95.6 and 91.6, respectively (P = 0.01). BIS and CSI prediction probability values (mean ± sd) were estimated to be 0.87 ± 0.08 and 0.86 ± 0.08, respectively (NS). The CSI tended to stabilize at values of 60-40 when estimated propofol concentrations at the effect site increased from 5 to 8 μg/mL. The BIS stabilized at values of 40-20 when the propofol concentrations at the effect site increased from 7 to 10 μg/mL. The mean BIS-CSI difference was -7.4 with 95% limits of agreement of 22.2 and -36.9. The BIS and CSI correlation with the burst suppression ratio was -0.60 and -0.97, respectively (P < 0.01). Predicted BIS and CSI values for loss of eyelash reflex in 50% and 95% of the patients were different (P < 0.05). CONCLUSION: The overall performance of both monitors during propofol induction was similar. However, the different dynamic profiles of these monitors indicate that BIS may be a more useful index for evaluating intermediate anesthetic levels, whereas CSI may be better for evaluating deeper anesthetic levels. © 2007 by International Anesthesia Research Society.
Más información
Título según WOS: | Performance of the cerebral state index during increasing levels of propofol anesthesia: A comparison with the bispectral index |
Título según SCOPUS: | Performance of the cerebral state index during increasing levels of propofol anesthesia: A comparison with the bispectral index |
Título de la Revista: | ANESTHESIA AND ANALGESIA |
Volumen: | 104 |
Número: | 3 |
Editorial: | LIPPINCOTT WILLIAMS & WILKINS |
Fecha de publicación: | 2007 |
Página de inicio: | 605 |
Página final: | 610 |
Idioma: | English |
URL: | http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00000539-200703000-00032 |
DOI: |
10.1213/01.ane.0000255152.96354.17 |
Notas: | ISI, SCOPUS |