Comparison of Different Fin and Tube Compact Heat Exchanger with Longitudinal Vortex Generator in CFU-CFD Configurations
Abstract
Over the last decades several studies have searched for improved Fin and Tube Heat Exchanger (FTHE) designs capable of providing the best thermo-hydraulic performance. The present study aims at quantifying and comparing the thermo-hydraulic performance of different FTHE configurations. Six different designs were analyzed. The first FTHE consisted of an in-line circular tube arrangement and the last one was a FTHE with staggered oval tube with two pairs of Delta Winglet Vortex Generators (DWVG) in common flow up-common flow down (CFU-CFD) configuration. The best performance was obtained using DWVG in CFU-CFD orientation. This configuration enabled a 90% increase of the thermal performance factor when compared with the first case, using only two pairs of vortex generator's per tube.
Más información
Título según WOS: | Comparison of Different Fin and Tube Compact Heat Exchanger with Longitudinal Vortex Generator in CFU-CFD Configurations |
Título de la Revista: | INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY |
Volumen: | 39 |
Número: | 5 |
Editorial: | INT INFORMATION ENGINEERING TECHNOLOGY ASSOC |
Fecha de publicación: | 2021 |
Página de inicio: | 1523 |
Página final: | 1531 |
DOI: |
10.18280/ijht.390514 |
Notas: | ISI |