Cellular Automaton Simulation of Corrosion in 347H Steel Exposed to Molten Solar Salt at Pilot Plant Scale
Keywords: corrosion, modeling, cellular automata, solar energy, csp, thermal storage
Abstract
The fast-paced depletion of fossil fuels and environmental concerns have intensified interest in renewable energies, with dispatchable solar energy emerging as a key alternative. Concentrated solar power (CSP) technology, utilizing thermal energy storage (TES) systems with molten salts at 560 °C, offers significant potential for large-scale energy generation. However, these extreme conditions pose challenges related to material corrosion, which is critical for maintaining the efficiency and lifespan of CSP. This research modeled the corrosion process of 347H stainless steel in molten solar salt (60% NaNO3 + 40% KNO3) melted at 400 °C using a cellular automaton (CA) algorithm. The CA model simulated oxide growth under pilot-plant conditions in a lattice of 400 × 400 cells. SEM-EDS imaging compared the model with a mean squared error of 2%, corresponding to a corrosion layer of 4.25 µm after 168 h. The simulation applied von Neumann and Margolus neighborhoods for the ion movement and reaction rules, achieving a cell size of 0.125 µm and 10.08 s per iteration. This study demonstrates the CA model’s effectiveness in replicating corrosion processes, offering a tool to optimize material performance in CSP systems. Additionally, continuing this investigation could contribute to developing industrial applications, enabling the design of preventive strategies for large-scale operations.
Más información
Título de la Revista: | MATERIALS |
Editorial: | MDPI Open Access Publishing |
Fecha de publicación: | 2025 |
Página de inicio: | 1 |
Página final: | 13 |
Idioma: | English |
Financiamiento/Sponsor: | ANID-Chile/ANID VIU24P0174; CONICYT/FONDAP 1523A0006 “Solar Energy Research Center” SERC-Chile; Engineering Project 2030 16ENl2-71940 Corfo; Doctoral Program in Solar Energy of Universidad de Antofagasta, Chile |
Notas: | WOS |