Vaginal power morcellation using a contained bag system: a novel surgical technique
Keywords: Power morcellation, laparoscopic, endoscopic pouch
Abstract
Background: To decrease the risk of unsuspected malignancies disseminating, several studies have shown the safety of using a containment bag to limit tissue dissemination during manual or power morcellation. Furthermore, in 2020, the FDA recommended performing laparoscopic power morcellation for myomectomy or hysterectomy only within a tissue containment system. Objective: To show step-by-step a new surgical technique using vaginal power morcellation within an endoscopic pouch without adding or extending other incisions. Materials and methods: Video article describing vaginal power morcellation. Results: To perform power morcellation through vaginal introit, additional operative time was only 13 minutes. Conclusions: Vaginal power morcellation using a contained bag system is technically feasible and efficient. Furthermore, it may prevent intraperitoneal dissemination of tissue fragments whilst minimising the need for additional surgical incisions.
Más información
Título según WOS: | ID WOS:001383141300012 Not found in local WOS DB |
Título de la Revista: | facts views and vision in obgyn |
Volumen: | 16 |
Fecha de publicación: | 2024 |
Página de inicio: | 493 |
Página final: | 495 |
Idioma: | Inglés |
DOI: |
10.52054/FVVO.16.4.044 |
Notas: | ISI |