Parallel oxygenators in the same circuit for refractory hypoxemia on veno-venous extracorporeal membrane oxygenation. A 3-patient series

Hurtado, Sebastian; Sepulveda, Veronica; Godoy, Cesar; Bahamondes, Rodrigo; Kattan, Eduardo; Mendez, Magdalena; Besa, Santiago

Abstract

Extracorporeal membrane oxygenator (ECMO) is a well-established therapy for respiratory failure. Refractory hypoxemia, despite the use of ECMO, remains a challenging problem. The ECMO circuit may not provide enough oxygenation support in the presence of high cardiac output, increased physiologic demand, and impaired gas exchange. Adding a second ECMO oxygenator using the same pump (sometimes needing a second drainage cannula) can improve oxygenation and facilitate lung-protective ventilation in selected patients. We describe a 3-patient series with severe ARDS secondary to SARS-CoV-2 infection and refractory hypoxemia during ECMO support successfully treated with this approach.

Más información

Título según WOS: Parallel oxygenators in the same circuit for refractory hypoxemia on veno-venous extracorporeal membrane oxygenation. A 3-patient series
Título de la Revista: PERFUSION-UK
Volumen: 39
Número: 8
Editorial: SAGE PUBLICATIONS LTD
Fecha de publicación: 2024
Página de inicio: 1715
Página final: 1721
DOI:

10.1177/02676591231220315

Notas: ISI