Diagnostic accuracy of 18F-PSMA-1007 PET/CT imaging for lymph node staging of prostate carcinoma in primary and biochemical recurrence

Sprute K.; Kramer, V.; Koerber S.A.; Meneses M.; Fernández, R.; Soza-Ried, C; Eiber M.; Weber W.A.; Rauscher I.; Rahbar K.; Schaefers M.; Watabe T.; Uemura M.; Naka S.; Nonomura N.; et. al.

Keywords: PSMA, 18F, 1007 PET/CT; Correlation; Histopathology; Lymph node staging; Prostate cancer

Abstract

Prostate-specific membrane antigen (PSMA)-ligand PET/CT is performed on patients with prostate cancer to stage the disease initially or to identify sites of recurrence after definitive therapy. On the basis of clinical results, 18F-PSMA-1007 is a promising PSMA PET tracer, but detailed histologic confirmation has been lacking. Methods: Ninety-six patients with prostate cancer underwent 18F-PSMA-1007 PET/CT followed by either radical prostatectomy with lymphadenectomy or salvage lymphadenectomy. The histologic findings of PSMA PET-positive nodes were analyzed retrospectively. A lesion-based and patient-based analysis was performed comparing all positive lesions and only lesions larger than 3 mm on histopathology. Results: Of the patients, 90.6% received 18F-PSMA-1007 PET/CT for staging before the primary treatment, whereas 9.4% underwent imaging for biochemical recurrence. In 34.4% of the cohort, positive lymph nodes were present on imaging. In total, 1,746 lymph nodes were dissected in 96 patients. 18F-PSMA-1007 PET had a lesion-based sensitivity of 81.7%, a specificity of 99.6%, a positive predictive value of 92.4%, and a negative predictive value of 98.9% for detecting positive lymph nodes larger than 3 mm. In the analysis of all malignant nodes regardless of size, the overall sensitivity, specificity, positive predictive value, and negative predictive value on lesion-based analysis were 71.2%, 99.5%, 91.3%, and 97.9%, respectively. The patient-based analysis showed a sensitivity of 85.9% and a specificity of 99.5% for lymph nodes larger than 3 mm. Conclusion: 18F-PSMA-1007 PET/CT reliably detects malignant lymph nodes and has an exceptional specificity of more than 99% for nodal metastases.

Más información

Título según SCOPUS: Diagnostic accuracy of 18F-PSMA-1007 PET/CT imaging for lymph node staging of prostate carcinoma in primary and biochemical recurrence
Título de la Revista: Journal of Nuclear Medicine
Volumen: 62
Número: 2
Editorial: Society of Nuclear Medicine Inc.
Fecha de publicación: 2021
Página final: 213
Idioma: English
DOI:

10.2967/jnumed.120.246363

Notas: SCOPUS